Fracture Probability Figure 8 shows the time history of thermal stresses (σ) and the effective volume (Ve), fracture probability (Pf) for a Model A (SiC ). It is shown that because of the smaller effective volume, the fracture probability of the nozzle is lower than approximately 10 % and this is considered to be similar to that of other test pieces. It is therefore considered that any Model A were not fractured in the thermal shock tests. On the other hand, the stress level of Model B is lower than that of Model A, but two nozzles were fractured in the tests. It is because the cause of fracture depended on the difference of fracture probability between Model A and Model B, which gave a higher value. This high fracture probability in Model B resulted from the difference of stress gradient between the two Models as shown in Figure 5(a) and (b). Figure 8: Time history of σ and Ve, Pf of Model A CONCULUSIONS A high-temperature thermal shock testing facility and fracture evaluating procedures for ceramic blades were developed. The typical fracture characteristics of ceramic turbine nozzle blade under instantaneous thermal shock condition were clarified and the fracture mode was presented. ACKNOWLEDGEMENTS This work was conducted under a contract from the Agency of Industrial Science and Technology of the Ministry of International Trade and Industry (AIST/MITI). We appreciate their advice and support. REFERENCES 1. Mikami, T. et al (1996). Status of the Development of the CGT301, a 300 KW Class Ceramic Gas Turbine, ASME 96-GT-252, ASME TURBO EXPO’96, Birmingham, UK 2. Mikami, T. et al (1998). Application of Ceramics to the CGT301, a 300 KW Class Ceramic Gas Turbine, CIMTEC 98, Florence, Italy