predict fatigue crack growth behaviour in the shear lip crack growing area, using crack growth rate data from the area without shear lips.. The principle of the calculation is that the K factor and the shear lip width are both influenced by the same, yet unknown (micro)mechanism. The shear lip width is then considered as a measure for K. The developing shear lip width rate is assumed to be proportional to the difference in actual shear lip width and the equilibrium shear lip width, being the width as would be found in a constant ∆K test after a large enough crack growth. Furthermore the model is applied to a situation with underloads in AA 2024. The underloads are high enough to give rise to slanted crack growth. The crack growth behaviour after different numbers of underloads is both measured and predicted. Experiments The chemical composition of the materials is as shown in the table: TABLE CHEMICAL COMPOSITION(WT %) OF AA 5083 AND 2024, REMAINDER AL AA Mg Mn Si Fe Cr Cu Zn Ti 5083 4.5 0.65 0.26 0.22 0.09 0.09 0.06 0.03 2024 1.18 0.67 0.34 0.14 0.004 4.75 0.19 0.03 The center-cracked specimens have a length of 340 mm, a width of 100 mm and a thickness of 8 mm (AA 5083) or 6 mm (AA 2024). The fatigue crack growth experiments are performed on a computer-controlled servohydraulic fatigue machine. The loading program is 0.001 0.01 0.1 1 10 1 10 100 ∆Keff/2 and ∆K (MPa√m) da/dN (µm/cycle) R=0.7 R=0.5 R=0.5 R=0.5 R=0.1 R=0.1 R=0.1 R=-0.25 R=-0.25 R=-1 R=-1 deltaKeffective 0.7 0.5 0.1 -0.25 -1 ∆Keff Figure 1. Results of 11 constant amplitude tests on AA 5083 at 5 different values of R and the corresponding da/dN-∆Keff (shifted a factor 2 to the left for clearness). offered to the machine in the form of a load table where the maximum load, the minimum load, the crack length and the frequency are specified.. The crack length is measured using a pulsed direct-current potential drop measurement system. The frequency is 10 Hz.
RkJQdWJsaXNoZXIy MjM0NDE=