ICF10B

-250 -150 -50 50 150 250 350 450 7 9 1113151719212325 Position (mm) Residual Stress (MPa) Front side Back side Average 0 10 20 30 40 50 60 7 9 1113151719212325 Crack length, a (mm) Residual SIF (MPa√m) Figure 2: Initial tangential residual Figure 3: Residual SIF calculated using stress along the prospective crack line. the weight function. 0 0.2 0.4 0.6 0.8 10 15 20 25 Crack length, a (mm) R' 1.E-05 1.E-04 1.E-03 1.E-02 10 12 14 16 18 20 22 24 Crack length, a (mm) FCP rate (mm/cycle) Experiment TC Walker Figure 4: (a) Effective load ratio, R’, as a Figure 5: Comparison of predicted and function of crack length for residual stress experimental crack growth rates with specimens. Constant applied SIF range ∆K=25 MPa√m. Plastic Zone Measurements Experimental determination of the plastic zone size along the crack line is shown in Figure 6. Even though the specimen experienced a constant maximum applied SIF of 25 MPa√m, the plastic zone size was found to increase as the crack entered the residual stress field. 0 1 2 3 4 5 6 7 8 9 10 14 15 16 17 18 19 20 21 22 23 24 25 Crack length (mm) Approximate vertical PZ size (mm) Experiment Dugdale (24) Birol (25) Irwin (26) Rice (27) Bathias(28) Figure 6: Vertical plastic zone sizes in the interior of the sample. Note the Dugdale and Birol solutions are nearly overlapped.

RkJQdWJsaXNoZXIy MjM0NDE=