ICF10B

ORAL REFERENCE: ICF10 0176OR FRACTURE AND FATIGUE CRACK GROWTH FOR MICRO-SIZED SPECIMENS K. Takashima and Y. Higo Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8503, Japan. ABSTRACT Fracture and fatigue tests were carried out on micro-sized specimens prepared from an electroless deposited Ni-P amorphous alloy thin film using a newly developed mechanical testing machine, and the size effects on the fracture and fatigue crack growth behavior have been discussed. Cantilever beam type specimens (10 x 12 x 50 µm3) with notches were prepared from a Ni-P amorphous thin film by focused ion beam machining. Fatigue crack growth tests were carried out in air at room temperature under constant load amplitude using the testing machine for micro-sized specimens. Fatigue crack growth resistance curves were obtained from the measurement of striation spacing on the fatigue surface. Once fatigue crack growth occurs, the specimens failed after several thousand cycles. This indicates that the fatigue life of micro-sized specimens is mainly dominated by crack initiation. Fracture tests were performed for the specimens with fatigue pre-cracks ahead of the notches. The plane strain fracture toughness, KIC, value was not obtained since the criteria of plane strain were not satisfied for this specimen size. As the plane strain requirements are determined by stress intensity and yield stress of the material, it is rather difficult for micro-sized specimens to satisfy these requirements. Plane stress and plane strain dominated regions were clearly observed on the fracture surfaces and their sizes were consistent with those estimated by fracture mechanics calculations. It is necessary to consider the results obtained in this investigation when designing actual MEMS devices. KEYWORDS Micro-sized specimen, MEMS, Fracture, Fatigue, Amorphous alloy, Thin film, Size effect INTRODUCTION Micro-sized machines and microelectromechanical systems (MEMS) are expected to be applied to bio-medical and micro-photonics devices such as micro-catheters for brain surgery and optical switches for electro-optical communications. The size of the components used in such MEMS devices is considered to be in the order of microns, and the mechanical properties of such micro-sized materials are considered to be different from those of bulk (ordinary sized) materials. Therefore, the evaluation of mechanical properties including elastic modulus, tensile strength, fracture toughness and fatigue properties are essential for practical applications of such MEMS devices. To date, there have been several studies which investigate the mechanical properties of small sized materials [1-3]. In particular, fracture toughness and fatigue crack growth properties of micro-sized materials are extremely important to enable reliable design of actual MEMS devices. In our previous studies, we have developed a new

RkJQdWJsaXNoZXIy MjM0NDE=