gas turbine system were seriously corroded by heavy molten salt such as Na2SO4 together with the high temperature oxidation[1]. Therefore it becomes important that the materials used in this system must be basically stable under these corrosive environments. Also, they must have superior thermo-mechanical properties. As mentioned before, non-oxide ceramics such as SiC and Si3N4 show excellent fracture strength, fracture toughness and thermal shock resistance when used under high temperature condition. However, these non-oxide ceramics fundamentally have unstable oxidizing character especially under heavy molten salt environment. Therefore, it is important to evaluate the effects of molten salt corrosion upon the mechanical properties of non-oxide ceramics. Therefore in this paper, corrosion characteristics and degradation of mechanical properties of Si-based structural ceramics such as SiC and Si3N4 by molten salt of Na2SO4 were investigated. Also, degradation mechanism of Si-based ceramics by molten salt was discussed. EXPERIMENTAL PROCEDURE Specimen Materials used in this study are SiC and Si3N4, which are mainly used for various parts of gas turbine engine. Square cross-sectional bar type test specimen (4×3×40mm) with a chamfered edge of 0.1 mm is cut from the sintered plate. Surface of specimen was finished by polishing to obtain mirror surface. The sintering method and chemical composition of Specimen are shown in the following Table 1. Table 1. Specimen Date Item SiC Si3N4 Sintering method Normal pressure sintering Gas pressure sintering Chemical Composition SiC, Na, Mg, Ca, Fe, Ti, Al, Y, B Si3N4, Al2O3, Y2O3 High Temperature Corrosion Tests and Strength Tests High temperature corrosion test was conducted employing Na2SO4 coated specimens. The Na2SO4 coating was conducted as follows. First of all specimen was immersed into the solution that 9.55 g of Na2SO4 was mixed to 0.1 litter of pure water. Dip coated layer of Na2SO4 was obtained on the surface of the specimen. Then, water molecule in coated layer was evaporated by drying. High temperature oxidation and corrosion tests at 1atm were conducted under various temperature conditions up to 1373K. Holding time for high temperature testing was ranged up to 8 hours. The degrees of progress of high temperature oxidation and molten salt corrosion were evaluated by the change of residual bending strength employing JIS R1601 4 point bending test [2] using each 2 specimens with and without molten salt Na2SO4 coating after various high temperature tests. The deflection rate is in bending test selected as 0.5 mm/min. The detailed microscopic observation of specimen surface and fracture surface was conducted by FE-SEM. EXPERIMENTAL RESURTS AND DISCUSSIONS The Strength Degradation by Molten Salt Corrosion The results of 4 point bending test obtain using non-oxidized and oxidized specimens of both SiC and Si3N4 under various high temperature conditions were shown in Figure 1. Both SiC and Si3N4 specimens without
RkJQdWJsaXNoZXIy MjM0NDE=