Fig.6 Anodic polarization curves of stainless steel for ELID ground specimen series) ; these values are less than that of other ELID ground specimens. 3.2 Corrosion test 3.2.1 ELID ground specimen Potentiodynamic polarization tests were carried out for the ELID ground specimen (Fig.6). During the anodic sweep of the test, the passive current densities of the specimens ground with the #2000 and the #8000 wheel, occurred in the applied potential range of 0.1 to 0.4 V vs S.C.E. The passive current density (Ipass) for #8000 series was higher than values observed for the #2000 series. No passive current density was observed for the #325 series with a relatively rough surface. Pitting potential (Epit) for the #8000 series was higher compared to the #325 and the #2000 series. Here, Epit is defined as the potential in which current density rapidly increased. This means that the corrosion property is superior with the scale of abrasives decreased. Fig.7 shows SEM micrograph of a pit observed after corrosion test. The corrosion pit generated along the grinding grooves. These results support the idea that the corrosion reaction is affected by the surface roughness. Fig.7 SEM micrograph of the corrosion pit -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 101 100 10-1 10-2 10-3 10-4 10-5 10-6 Potential (V vs S.C.E) Current density (mA/cm2) (2) (3) (1) (1) #325 series (2) #2000 series (3) #8000 series
RkJQdWJsaXNoZXIy MjM0NDE=