specimen length on the recorded load trace (Figure 3b): the greater the specimen length, the greater the inertia of the wings, the longer the duration of this stage. This interpretation is supported by observations drawn from the experiments performed on specimens bearing added concentrated masses. Placing the weights at the center of the test bar produces the same effect 0 100 200 300 400 500 0 0.1 0.2 0.3 Load (N) Time (ms) L/W=6.1 a/W=0.5 0 0.1 0.2 0.3 Time (ms) L/W=6.1 a/W=0.5 Figure 4 – Comparison of first peak records obtained from specimens of identical dimensions but with added concentrated masses placed either at mid-span (full line, left) or at specimen ends (full line, right). Dotted line: un-ballasted specimen. as increasing the contact mass: both the intensity and the duration of the force pulse increase, as predicted by elementary mechanics (Figure 4, left). Placing the weights at the extremities of the test bar increases the inertia of the wings just as by increasing the specimen length, and the effect is an extension of the descending part of the force peak (Figure 4, right). Subsequent peaks It was shown previously [5,1] that number and separation of the subsequent peaks change by varying the notch depth a, and the time interval between two consecutive peaks turned out to be proportional to the square root of the “static” bending compliance in three-point bending, at least for specimens of “standard” three-point bend dimensions (S/W = 4 and L ≈ S) [1]. The investigation has now been extended to consider the effect of increasing the specimen length and adding some concentrated masses. An example of the results so obtained is shown in Figure 5. Number, shape and separation of the force peaks are all affected. In an attempt to rationalize the dependence of the separation between the main peaks on specimen length, we have plotted the time interval between the first two main peaks A and B, TAB, (assuming it is proportional to the fundamental vibrational period of the beam) as a function of the square root of the dimensionless “static” bending compliance in three-point bending, ψ (a/W, L/W) calculated from [8,9] according to [2] with S = L (Fig. 6). The diagram collects all data points measured in the present work, with a/W ranging from 0.15 to 0.75 and L/W ranging from 4.4 to 8.6. The points appear to fall nicely on a single straight line through the origin. This finding confirms (as to the a/Wdependence) and extends (as to the L/W-dependence) the validity of the argument set out in [1]: the “dynamic” one-point bend compliance is proportional to the “static” three-point bend compliance, as specimen wings inertia acts like a constraint on the wings movement just as the anvils do in the three-point testing mode. This result further strengthens the data interpretation given in [1]: the series of force peaks observed during the test reflects successive impacts of the striker tup onto the specimen, resulting from flexural vibrations of the moving specimen.
RkJQdWJsaXNoZXIy MjM0NDE=