ICF10B

Industrial grade purity platinum and industrial use Pt-10wt%Rh alloy ingots were hot forged at 1473K. After they were forged, they were cold rolled to 10mm thickness and annealed at 1373K for half an hours. Then they cold rolled to 1mm thickness. ZrO2 dispersion strengthened platinum ingot was hot forged at 1473K. After it was forged, they were cold rolled to 10mm thickness and annealed at 1673K for an hour. Then they cold rolled to 1mm thickness. Specimens were punched from the sheets. Their dimensions were 2.5mm wide and 20mm long. The surface was polished with alumina powder, and it was finished in the specularity. The fatigue test was carried out in 20Hz frequency, sine wave of R=0.1 stress ratio, in the vacuum at room temperature and 1073K under the load control. RESULTSANDCONSIDERATION S-N chart Relationship between rupture number of cycles (Nf) and stress amplitude (S) of the PtRh alloy explained above was measured in the vacuum at 293K and 1073K. The results are summarized in Figure-1. S-N characteristics of the PtRh alloy was regressed as the straight line. Fatigue strength of the specimen defined as stress amplitude at 107 cycles was 100MPa at 293K and 30MPa at 1073K. 0 103 105 106 107 102 104 Number of cycles to failure :Nf (cycle) Stress amplitude:S MPa 108 10 20 30 40 50 60 70 80 90 100 110 120 130 PtRh10%,1073K,20Hz PtRh10%, 293K,20Hz Fig.1 S-N curve of PtRh material SEM observation and analysis of the specimen done fatigue breakdown at 1073K Fracture surface analysis was carried out for the specimens after they broke in order to clarify high temperature fatigue characteristics of the PtRh alloy. Fracture surface photograph in short life (S=60MPa, 1073K) is shown in figure 2. Figure 2(a) is low magnification, and (b) is a fracture surface of high magnification. From figure 2(a), there was sliding necking in the fracture surface, and it was proven to be the typical ductile fracture. (a)Low magnification (b) High magnification (a)Low magnification (b) High magnification Fig.2 SEM photograph of fracture surface (S=60MPa) Fig.3 SEM photograph of fracture surface (S=45MPa) Fracture surface photograph in long life (S=45MPa, 1073K) is shown in figure 3. Figure 3(a) is at low magnification, and (b) is a fracture surface of high magnification. From figure 3(a), there was sliding necking in the fracture surface, and it is considered to be ductile fracture. Different from the fracture surface of short life sample shown in figure 2(b), a lot of dimples were observed on entire fracture surface of long life sample as shown in figure 3(b). It is assumed through the phenomena that creep deeply affected dimple generation and they were made under conditions of dynamic fatigue breakdown. There is a transition of the failure mechanism that effect of creep increases with decrease of stress. In other words, in the high stress ()

RkJQdWJsaXNoZXIy MjM0NDE=