without an applied stress, with applied compressive stresses of –800 and –200 MPa, and with applied tensile stresses of 100 ~ 800 MPa. The specimen surfaces were observed using a Scanning Electron Microscope (SEM) to examine corrosion reaction of the samples. Auxiliary electrode Reference electrode Specimen Ringer’s solution Thermostatic chamber Axial load Potentiostat Figure 2: Schematic of the corrosion test system 3. RESULTS 3.1. Anodic polarization curve of the specimen without an applied stress The solid line in Figure 3 (a) shows the anodic polarization curve of the specimen without an applied stress. It can be seen that passive current density is 3.0 µA/cm2 (1 V vs. SHE) and breakdown potential is 2.5 V vs. SHE (We define the breakdown potential as the potential at which current density exceed 10 µA/cm2). Above the breakdown potential, the current density increases significantly as the potential becomes more positive because pitting initiates and propagates. This region of the anodic polarization curve is called the transpassive region. The reverse sweep of the scan closely retraces the path of the forward scan. This indicates that the pitted region repassivates immediately. Consequently, Ti-4.5Al-3V-2Mo-2Fe alloy has a high corrosion resistance in Ringer’s solution. 3.2. Anodic polarization curves of the specimens under applied compressive stresses The Anodic polarization curves of the specimens with applied static stresses of –200 MPa (a dotted line in Figure 3 (a)) and –800 MPa were similar to the ones of the specimen without an applied stress. Figure 4 shows the passive current densities (solid squares) and breakdown potentials (open circles) of these tests. These values seem to be independent of stresses between 0 ~ -800 MPa. This implies that static compressive stress has no significant effect on corrosion behavior. 3.3. Anodic polarization curves of the specimens under applied tensile stresses The anodic polarization curve of the specimen under an applied stress of 100 MPa is shown in the dotted line in Figure 3 (b). The curve is similar to the one without an applied stress. This suggests that static tensile stress of 100 MPa has no effect on corrosion behavior. During the anodic sweep at below 3.8 V vs. SHE, the anodic polarization curve of the specimen under an applied tensile stress of 200 MPa (the broken line in Figure 3 (b)) is similar to the one of the specimen without an applied stress (the solid line in Figure 3 (a)). As shown in Figure 4, in this anodic polarization test, the passive current density (the solid square) and the breakdown potential (the open circle) are approximately the
RkJQdWJsaXNoZXIy MjM0NDE=