same as those of the specimen without an applied stress. However, at 3.8 V vs. SHE in a transpassive region, the current density suddenly increased to 200 mA/cm2, and stayed at a high value during the cathodic sweep. Such sudden current density increase was also found with applied tensile stresses of 400 ~ 800 MPa at 3.8 ~ 4.1 V vs. SHE. These results suggest that static tensile stress of 200 ~ 800 MPa has no effect on corrosion behavior at below or about 4 V vs. SHE. However, this stress greatly accelerates dissolution at this potential in a transpassive region. 0 1 2 3 4 10–6 10–3 100 103 Potential, V vs. SHE Current Density, mA/cm2 0 1 2 3 4 10–6 10–3 100 103 Potential, V vs. SHE Current Density, mA/cm2 Figure 3: Anodic polarization curves for Ti-4.5Al-3V-2Mo-2Fe alloy in Ringer’s solution at 37°C 100 MPa -200 MPa 200 MPa zero stress (a) (b) –500 0 500 100 103 0 1 2 3 4 Stress, MPa Breakdown Potential, V vs. SHE Passive Current Density, A/cm2 µ Figure 4: Passive current densities and breakdown potentials obtained by anodic polarization tests 3.4. Observation In order to examine the corrosion reaction under tensile stress before the sudden current density increase at about 4 V vs. SHE, an anodic polarization test was conducted under an applied tensile stress of 400 MPa. After the current density reached 1 mA/cm2, the test was terminated and the surface of the specimen was observed using SEM. A Typical feature of the corroded surface is shown in Figure 5. Dissolutions in the β-phase and corrosion products were found. Similar phenomena were also observed after the anodic polarization tests with compressive stress of –200 MPa and zero stress. Therefore, the corrosion reaction with either tensile stress or compressive stress turns out to be the same as the corrosion reaction under zero stress before sudden current density increase at about 4 V vs. SHE.

RkJQdWJsaXNoZXIy MjM0NDE=