Axial load 3 µm Figure 5: SEM observation of dissolutions in the β-phase and corrosion products To explain the reason for the sudden current density increase at about 4 V vs. SHE, an additional anodic polarization test was carried out with a tensile stress of 400 MPa. The test was terminated 7 min after sudden increase, and the surface of the specimen was examined. Macroscopic damage at the center of the test surface was observed (Figure 6). However, the rest of the surface was similar to that of Figure 5. This means that the sudden increase in current density is probably because of a great dissolution in the localized area as shown in Figure 6. Most of the test surfaces were damaged similarly and there was only one damage on one test surface after anodic poralization tests with constant stresses of 200 ~ 800 MPa. Figure 6: SEM observation of large damage at the center of test surface 1 mm Axial load 4. DISCUSSION In this study, the effects of static stress on corrosion behavior of Ti-4.5Al-3V-2Mo-2Fe alloy were investigated. We conclude that constant compressive stress and tensile stress of below 100 MPa have little effect on corrosion behavior because the anodic polarization curves and the feature of the corroded surfaces were similar to the one under zero stress (Figures 3 (a), and 4).
RkJQdWJsaXNoZXIy MjM0NDE=