With applied static tensile stresses of 200 ~ 800 MPa at below or about 4 V vs. SHE, the anodic polarization curves and the surface feature were also similar to those without an applied stress (Figures 3, 4, and 5). Thus, we conclude that the corrosion reaction with static tensile stress of 200 ~ 800 MPa at below or about 4 V vs. SHE is the same as those under zero stress. On the other hand, with static tensile stresses of 200 ~ 800 MPa, current densities increased suddenly at about 4 V vs. SHE in a transpassive region (Figure 3 (b)). To investigate the reason, anodic polarization with an applied stress of 400 MPa was conducted and terminated 7 min after sudden current density increase. Macroscopic damage was observed on the test surface (Figure 6) while the rest of the surface was similar to the one without an applied stress. From these results, static tensile stress of 200 ~ 800 MPa makes great dissolution in a localized area at about 4 V vs. SHE in a transpassive region. The shape of the damage (Figure 6) suggests that microscopic damage spread to the macroscopic damage. With these stresses, current densities kept at a high value after sudden current density increase and there was only one damage on each test surface after the anodic polarization tests. These results suggest that localized macroscopic damage propagates over most of the test surface. In conclusion, static tensile stress of 200 ~ 800 MPa greatly accelerates dissolution at about 4 V vs. SHE in a transpassive region. This phenomenon might be the cause of corrosion fatigue and toxicity in vivo. Further study of the influence of stress on corrosion behavior of titanium alloy is needed to examine whether this phenomena would take place in vivo. 5. CONCLUSIONS In the present study, anodic polarization tests were carried out in constant stress conditions to clarify the effects of static stress on corrosion behavior of Ti-4.5Al-3V-2Mo-2Fe alloy in Ringer’s solution at 37°C. We conclude as follows. Static compressive stress up to -800 MPa and tensile stress of below 100 MPa appears to have little effect on corrosion behavior. With applied static tensile stresses of 200 ~ 800 MPa, current density increases suddenly during the anodic polarization tests at about 4 V vs. SHE, which is about 1 V higher than the breakdown potential for pitting. At below or about 4 V vs. SHE, the corrosion reaction is the same as the corrosion reaction under zero stress. On the other hand, great dissolution takes place in a localized area at about 4 V vs. SHE, while the rest of the test surface is similar to the one below this potential. REFERENCES 1. Sumita, M. (1997) Journal of Japanese Society for Biomaterials, 15-5, 240 2. Kawahara, H. (1992) Bulletin of the Japan Institute of metals, 31-12, 1033 3. Yu, Q. W., Morita, M., Itoman, M., and Sasada, T. (1993) Journal of Japanese Society for Biomaterials, 11-1, 27 4. Bundy, K. J., Marek, M., and Hochman, R. F., (1983) Journal of Biomedical Materials Research, 17, 467
RkJQdWJsaXNoZXIy MjM0NDE=