ICF10B

a r W a Z r W a V t t t − + + − = ) ( ) ( δ (11) where W——width of test specimen; at——crack length calculated from loading line of the specimen, mm; V——crack mouth opening displacement, mm; Z——thickness of cutting edge, for SCT specimen, Z=0; r——rotational factor, calibrated through test. By conducting test calibration on SCT specimen with cracks of different length, the measured rotational factor r is about 0.28, yet this value basically does not vary with crack length and load. With the clamp-type tensiometer fixed on the crack mouth, we measured the crack mouth opening displacement V at each load during loading process, the results are shown in Fig. 5. From the measured V and calibrated r, we can obtain COD δ according to formula (11). (2) δ-e curve Take δ measured on the specimen with cracks and the peak strain e (0.5mm away from opening periphery) measured on the specimen without cracks under the same load as the coordinates of δ-e curve, join the marked points that correspond to each load during the whole test process, they become δ-e curves, as shown in Fig. 6. Plot expression (5), (9) and (10) onto the diagram at the same time, it can be seen that the test data points basically lie above the curves of expression (9) and (10), indicating that this expression can be taken as the calculation expression for fracture assessment of the cracks in high-strain zone. Fig. 6 δ-e curve of SCT specimen 4. EXPERIMENTAL RESEARCH ON FATIGUE CRACK PROPAGATION IN HIGH-STRAIN ZONE OF SCT SPECIMEN 4.1 Test Method And Conditions For Fatigue Of SCT Specimen Fig.5 P-V curve of SCT specimen The test conditions for the fatigue of SCT specimen are listed in Table 1. The crack length is determined simultaneously by outlining method and unloading flexibility method. Outlining adopts load-reducing outlining method[7], the number of cycles is acquired and recorded automatically by computer. TABLE 1 TEST CONDITIONS FOR FATIGUE OF SCT SPECIMEN Specimen No. Opening diameter mm Max. load kN Load ratio R Loading frequency Hz Length of prefabricated crack mm Remarks SCT6 25 8.0 0.05 8.0 1.31 17kN prestretching SCT7 25 8.0 0.05 8.0 1.31 4.2 Measurement Of Closing And Opening Force Of Fatigue Cracks In the process of fatigue crack propagation, a residual tensile strain zone remains in front of crack tip, this residual deformation reduces crack opening displacement, the external elastic zone compresses the plastic zone of crack tip during unloading, making compression stress occur near crack tip after unloading, even reach reverse yielding. When reloading, load increase eliminates compression stress of crack tip, the crack fully opens. From this time the load indeed contributes to crack propagation. The closing effect of fatigue cracks in plastic zone has a bigger effect on fatigue crack propagation. Therefore, the closing and opening force of fatigue cracks of SCT specimen are measured during the test. 4

RkJQdWJsaXNoZXIy MjM0NDE=