ICF10B

D extended approximately 3 mm and 1.5 mm prior to linking up. Specimen MSD5_16, which had the same crack configuration as MSD5_08, was subjected to three cyclic loads. At each cycle, the load was increased until crack tip D extended approximately 0.8 mm. The specimen was then unloaded to 10% of the maximum load. Experimental T*ε was evaluated for each crack extension as the specimen was cyclic loaded. Figure 3(c) shows that T*ε values under cyclic and monotonic loads are the same during crack growth. Thus the T*ε generated from a monotonically loaded CN specimen may also be used to characterize low cycle fatigue crack growth. Dynamic Crack Propagation Dynamic T*ε has been previously determined experimentally using the laser caustic method by Nishioka et al in 1991 [10]. In this study [11, 12], dynamic moiré interferometry was used to determine the transient displacement fields perpendicular and parallel to the running crack in 7075-T6 aluminum alloy, single edge notch (SEN) specimen. The SEN specimen was either fatigue precracked or blunt notched for low and high crack velocity tests, respectively. By neglecting the contour integral behind the propagating crack, only a partial near-crack contour at ε = 2 mm from the crack was used in the integration process thus simplifying the T*ε computation. The measured crack tip displacement field was also used to compute the LEFM-based strain energy release rate, G. Data in Fig. 4 identified as the first series is from Lee, Kokaly and Kobayashi [11] using fatigue precracked specimens and the second series refers to the data from the blunt notched specimens [12]. When plotted in terms of the crack velocity, the combined first and second series of tests, T*ε increased with increasing crack velocity and eventually leveled off at a terminal velocity of about 300 m/s as shown in Fig. 4. Literature on dynamic fracture show that the LEFM based dynamic strain energy release rate, GID with respect to crack velocity exhibits a characteristic gamma-shaped curve. The LEFM based GID for the dynamic fracture tests of 7075-T6 aluminum specimens and the blunt-notched 7075-T6 SEN specimens of Kobayashi and Engstrom [13] did yield this gamma-shaped curve. The LEFM approach results in a terminal velocity, which is insensitive to the variation in the driving force, GID, while the T*ε approach, based on elastic-plastic fracture mechanics (EPFM), suggests that the terminal crack velocity is a consequence of the saturation of the dissipated plastic energy. Γε=1mm Γ ε=1mm Crack Extension (mm) 0 1 2 3 4 T*ε (MPa mm) 0 20 40 60 80 100 120 140 160 Crack D Crack C Crack B CN - CN10 Crack Extension (mm) 0 1 2 3 4 5 6 T*ε (MPa mm) 0 20 40 60 80 100 120 140 160 Crack D Crack C CN - CN10 Crack linkup Crack linkup (a) MSD5_08. (b) MSD5_13. . D C B A Γ ε=1mm Crack Extension (mm) 0 1 2 3 4 5 6 T*ε (MPa mm) 0 20 40 60 80 100 120 140 160 Crack D Crack C CN - CN10 Crack linkup (c) MSD5_16. (d) Crack configuration. Fig. 3. T*ε associated with stable crack growth.

RkJQdWJsaXNoZXIy MjM0NDE=