Figure 1. 3-point bending specimens Figure 2. Orientation of CR and CL specimens as related to the carbide layers CL carbide layers CR applied load observed area Results of the Experiments The force-displacement curves were recorded during the tests. The loading was carried out in small steps, with the rate of loading about 1 mm/s. The places in the specimen notch where the microcrack initiation was expected have been observed through scanning electron microscopy (SEM) during the tests. It was observed that the first microcracks formed only in the primary carbides, and not in the “matrix” of the steel. Also, no microcrack along the carbide/matrix interface was observed in the tests. The forces at which the failure of primary carbides was observed in each specimen are given in the Table 1. TABLE 1. CRITICAL FORCES IN THE EXPERIMENTS . Numbers of specimens Type of the specimen Force at which first microcrack was observed in the specimen, N Force at which the specimen failed, N 1-3 KALC 95, 52, 37.5 155, 85,160 4-6 KACR 50, 55, 37.5 95, 95, 70 7-9 HSCR 45, 50 (several microcracks in both large and small carbides), 50 95, 80, 95 11-12 HSLC 50 (one microcrack), 72.5 (another microcrack), 127 200, 190, 195 Generally, the course of failure of the specimens was as follows: (1) formation of a microcrack at some carbide, (2) formation of several microcracks at many carbides in different places of observed area (in so doing, the microcracks are formed rather at larger carbides at some distance from the boundary of the specimen, than in more strained macroscopically areas in the vicinity of the lower boundary of the specimen; the local fluctuations of stresses caused by the carbides have evidently much more influence on the microcracking than the macroscopic stress field), and (3) after the failure of many carbides, the microcracks (or plastic zones in front of the microcracks) begin to grow into the matrix; just after this occurs, the specimens fail. The failure of many carbides was observed just before the specimens failed. The differences between the loads at which the microcracks are formed, and that at which the specimen failed was in most cases very small. Figure 3 shows 3

RkJQdWJsaXNoZXIy MjM0NDE=