ICF10B

newly generated martensite brings about high compressive residual stresses and a higher surface hardness and distinctly improves the wear resistance under sliding wear in air as well as in artificial sea water [6]. Both should improve the life time of wear and corrosion resistant parts and tools. But, the endurance life might be limited by deteriorated fatigue and fracture properties. In this paper the influence of the laser surface heat treatment on the fatigue properties is presented and discussed. With respect to the application of the HNS X30CrMoN15 1 (1.4108 = AMS5898) in aerospace industries the tests have been carried out in air as well as in artificial sea water. EXPERIMENTAL PROCEDURES Materials and Heat Treatments Before the laser treatments HNS discs of 100 mm diameter and 10 mm thickness were heat treated as follows: 30min/1200°C/oil+10min/-196°C/air+3x2h/620°C/air. The chemical composition of the HNS is given in Table 1. Figure 1 shows the microstructure, which consists of tempered martensite with less than 2 vol.-% of retained austenite (RA). Afterwards the specimens were laser-heat treated using a 3kW Nd:YAG-laser. The power of the laser was controlled by the maximum surface temperature Tmax in the heat treated area. The beam had a cross section of 14 x 1,8 mm transversally to the moving-direction (Figure 2) and was moved with a speed of 100 mm/min over the surface under an atmosphere of 15 l/min N2 and 0,13 Figure 1: Tempered Martensite of Heat Treated X30CrMoN15 1 with less than 2 % Retained Austenite. Figure 2: Design of the Specimens for Laser Surface Heat Treatment and Fatigue Testing.

RkJQdWJsaXNoZXIy MjM0NDE=