micromaterials were brought about due to miniaturization of materials in microelectromechanical systems (MEMS) devices [1-3]. However, as many microcomponents, such as micro radio frequency switches, etc. are constantly subjected to a cyclic load with a high frequency during the period of their service, fatigue properties of micro-sized materials should be a more important factor for a long-term reliability of microcomponents [4,5]. On the other hand, fine- or super fine- grained materials are widely used in MEMS devices in the form of thin films, which are deposited on Si substrates. Therefore, the study on mechanical properties, especially fatigue properties of such a fine-grained material provides not only a database of mechanical properties for the design of MEMS devices, but also an insight into the fundamental fatigue mechanism. In this study, a micro-sized austenitic stainless steel with fine grains was selected. Fatigue properties of the fine-grained material were investigated by dynamic bending tests. EXPERIMENTAL The material used in this study was a commercial 304 stainless steel thin sheet with fine grains. The microstucture of the material observed by Focused Ion Beam (FIB) machining system exhibited that the grain size was about 1-3 µm in diameter, as shown in Fig. 1. The micro-cantilever beam type specimens were fabricated at the center of a 3 mm-diameter disk with 25µm thickness by FIB machining [6]. The dimensions and shape of the microbeam is shown in Fig. 2. The distance from the loading point to the fixed end of the microbeam was 50 µm. 50 µm 50 µm 30 µm 25 µm Load Figure 2: Dimensions and shape of the micro-cantilever beam type specimen fabricated by FIB machining. 15 µm Figure 1: FIB observation of the grain size of the fine-grained austenitic stainless steel. Dynamic bending tests of the microbeams were carried out using a new type of fatigue testing machine for micro-sized specimens. This machine is of a displacement resolution of 5 nm and a load resolution of 10 µN [5]. The various waveforms for cyclic loading and frequencies up to 100 Hz can be applied using this machine. Before testing, the diamond tip was precisely located at the loading point by the repeated calibrations using the CCD camera, and then the micro-cantilever beam was dynamically bent under constant load amplitude control. The load ratio R (R=Pmin/Pmax) was 0.15 and the frequency was 10 Hz. All tests were stopped after about 4.5×105 cycles to examine fatigue damage on the specimen surfaces by scanning electron microscopy (SEM).
RkJQdWJsaXNoZXIy MjM0NDE=