The holes had a pattern with hole density, diameter and angel to surface as found in the leading edge, where a „shower head“ cooling is applied, giving the highest cooling hole density. Comparative specimens without holes had the same shape. To investigate the influence of different secondary orientations on the fatigue life some specimens were drilled with 45° secondary orientation in the planar gauge length (see Fig. 2). The LCF tests were performed on a servohydraulic test machine with inductive heating under total strain control. The integral strain on the gauge length of the sample was taken as the control signal. The SC-Nibasis superalloy PWA 1483 was investigated at temperatures of 900°C and 700°C, which are typical temperatures for material close to the outer and inner surfaces of the first stage blade. The loading during gas turbine operation is predominately controlled by thermal strain. This results in compressive strains at the hot outer surface and tensile strains at the colder inner surface. Therefore the strain ratio R=εmin/εmax was equal -∞ for 900°C test temperature and equal 0 for 700°C test temperature. A camera system was used to continuously observe the surface of the specimens during the fatigue tests. It was composed of two CCD-Cameras with specially developed control programs so that the crack initiation and propagation could be recorded automatically by computer. After tests, an evaluation was made for crack behaviour relating to the hole pattern and to micro-cracks. The failure cycles Nf were defined as the cycle number after which a drop of the stress amplitude of more than 5% was found. RESULTS AND DISCUSSIONS Fatigue Test Results Fig. 3 shows the LCF-life in form of the S-N-curves based on the integral strain range for specimens at 900°C and 700°C test temperature. Specimens with 45° secondary orientation are marked separately. Figure 3: Influence of cooling holes and holdtime For both temperatures it can be seen that the number of cycles to failure Nf for the samples with holes are lower at all strain levels. This is obviously due to the stress concentrations at the holes. The 45°- secondary orientation has hardly influence on the LCF-lifetime compared to the results of the mainly tested specimens with 0° secondary orientation. In Fig. 3 a) a further reduction of the fatigue life was caused by a holdtime of 20 minutes at the maximum compressive strain. In contrast with that the tests with holdtime at maximum tensile strain for 700°C (Fig. 3 b)) reach a higher cycle number to failure than the tests without holdtime. This could be explained through mean stress relaxation. 100 1000 10000 100000 0,3 1 2 a) T=900°C; R=-oo Special LCF-Samples: without holes with holes: 0°; ( ) 45° 20 min. holdtime 0°; ( ) 45° lg Nf lg Integral Strain Range normalized 100 1000 10000 100000 0,3 1 2 b) T=700°C; R=0 lg Nf lg Integral Strain Range normalized
RkJQdWJsaXNoZXIy MjM0NDE=