ICF10B

MATERIAL AND EXPERIMENTAL The material used was Fe-0.37C-0.4Si-0.60Mn-13.5Cr-1.0Mo (wt%) martensitic stainless steel strip with a thickness of 0,38mm. Four variants with retained austenite from 0,4vol% to 14,3vol% were investigated. Table 1 shows amounts of retained austenite and the mechanical properties. The tensile strength and hardness were indirectly increased with increasing retained austenite, but reached maximum values at about 10vol% retained austenite. The plasticity (elongation and bendability) was also improved with increasing retained austenite. TABLE 1 AMOUNT OF RETAINED AUSTENITE AND MECHANICAL PROPERTIES Variants Retained austenite (γ’) (%) Rp0.2 [MPa] Rm [MPa] A [%] Bendability* HV1 Strip-A 0,4 1420 1783 7,4 17,6 555 Strip-B 4,4 1487 1910 7,6 16,6 570 Strip-C 10,1 1490 1948 9,5 13,7 582 Strip-D 14,3 1427 1930 11,4 9,5 577 *Bendability: the ratio of the minimum radius to the specimen thickness at which a strip does not fail when it is bent. This is usually called Wertzahl value. The microstructure and fracture were investigated using SEM. For the microstructure investigation, the samples were etched in a solution consisting of 15 grams CuCl, 300 ml ethanol, 300 ml HCl and 300 ml H2O. The precipitation states were investigated on the thin foils using Jeol 2000FX TEM/STEM equipped with Oxford ISIS EDX system. Residual stresses were measured with an X-ray diffractometer using CrKα radiation. The damping capacity was determined using a simple experiment [3]. One end of the specimen was clamped horizontally and another was kept free. A steel ball with diameter of 17,5 mm and mass of 22 gram was dropped from a position of 300 mm above the sample. The changes in amplitudes of the free vibrations of the specimen were recorded using an oscilloscope. The damping capacity was evaluated by the following exponential approach: U=Uo exp(-bt) (1) where U is the amplitude at any vibration time, t is the time, Uo is the amplitude at t=0, and b is the damping index that is used to describe the damping capacity of material. Three types of fatigue testing, namely pulsating tension, bending and impact, were performed in a laboratory environment at room temperature. Pulsating tensile fatigue test (R=0) was performed using a Amsler test machine with a frequency of about 150Hz. Reversed bending fatigue test (R=-1) was performed using a UMG test machine with a frequency of 25 Hz. Impact fatigue tests were performed using Sandvik Impact Fatigue Tester with a frequency of 250 Hz [3]. The fatigue strength was determined using the staircase method with 50 % fracture probability [4]. A series of 30 specimens were used. The specimen was tested at a given level of a stress until it failed, or till maximum 2.106 cycles for pulsating tension and bending and 1·107 cycles for impact. The impact fatigue strength is the impact speed (m/s) at which the specimen hits the seat [3].

RkJQdWJsaXNoZXIy MjM0NDE=