ICF10B

-700 -600 -500 -400 -300 -200 0 4 8 12 Retained austenite (%) Residual stresses (MPa) 16 0.35 0.36 0.37 0.38 0.39 0.4 0.41 0.42 0.43 0 4 8 12 16 Retained austenite (%) Damping index, b Figure 3: (a). Influence of retained austenite (vol%) on the compressive residual stresses; (b). Influence of retained austenite on the damping capacity. (b) (a) Fatigue Strengths The fatigue strengths from the different tests are summarised in Figure 4. The impact fatigue strength was significantly increased with the increase of the amount of retained austenite. However, increase of the amount of retained austenite had little effect on the pulsating tensile fatigue strength. For bending fatigue, the fatigue strength was increased with increasing retained austenite, and reached a maximum at about 4vol% retained austenite. However, the bending fatigue strength was still higher in the material with larger amount of retained austenite (or not lower in the material with 14,3vol% retained austenite) than in the material with 0,4vol% retained austenite. 3.5 4 4.5 5 5.5 6 6.5 0 4 8 12 Retained austenite (%) Impact fatigue strength (m/s) 16 500 600 700 800 900 0 4 8 12 Retained austenite (%) Fatigue strength (MPa) 16 pulsating tension bending Figure 4: (a). Influence of retained austenite (vol%) on the impact fatigue strength; (b). Influence of retained austenite on the fatigue strengths in tension and in bending. (a) (b) DISCUSSION Precipitation Strengthening In Table 1, it shows that the tensile strengths increased with increasing retained austenite in the strips. Austenite is a soft phase comparing with the matrix (martensite phase). It is unlikely that the presence of retained austenite could result in the increase of the tensile strength or hardness. The strengthening or hardening, therefore, could be attributed to the precipitation of densely dispersed fine M23C6 and Fe3C particles as shown in Figure 1 and 2. Hence, the changes in the strengths or hardness were the resultant of the precipitation strengthening and softening due to the increase of retained austenite. It reached a maximum value at about 10vol% retained austenite. Slight decrease in the strength or hardness was owing to the large amount of retained austenite. Influence of Retained Austenite on Fatigue Behaviours As shown in Figure 4a, increase in retained austenite significantly improved the impact fatigue strength. This is quite promising since this property is very critical to compressor valve steels.

RkJQdWJsaXNoZXIy MjM0NDE=