continuous reinforcement fiber ends on low-cycle fatigue behavior for Ti-alloy matrix composite. MATERIALS AND EXPERIMENTAL PROCEDURE Materials and Test Specimens The materials investigated are unidirectional six- and seven-plies SCS-6/SP700 laminate composites. The composite panel was fabricated by hot isostatically pressing alternate layers of continuous SiC fibers, SCS-6 and thin Ti-alloy foils, SP700. Specimens used here are coupon-type with a dimension of 150 mm-long, 10 mm-width and 15 mm-gage length of 1.4~1.6 mm thickness as shown in Fig. 1. Taking account of the processing method of TMCs rotor bladed ring, two types of test specimen were prepared to examine the influence of reinforcement fiber ends on low cycle fatigue behavior. The simulated reinforcement fiber ends were introduced in the first ply layers light under specimen top surface (Type-I) and in the middle ply layer (Type-II) at the center of the gage section. Experimental Procedure The low-cycle fatigue tests lower than 105 cycles were performed at RT, 450 and 650℃ under strain-controlled mode at a frequency of 0.5 Hz with a constant strain ratio Rεof 0.1 using a MTS 810 TestStar materials testing system. Measurements of cyclic stress-strain curves were conducted using extensometer with 10 mm gage length. Cycles to failure Nf was determined at a number of cycle of 25 % load-drop from the initial steady state. After the fatigue testing, fractographic examinations were performed on specimen surface and fracture surface in order to examine the low cycle fatigue crack initiation and propagation mechanism 1 0 Type-II Type-I 10 150 15 47.5 Reinforcement fiber direction 6 1.4~1.6 R100 Ti-alloys 47.5 Figure 1: A schematic illustration of simulated reinforcement fiber ends and configuration and dimensions of fatigue test specimen. EXPERIMENTAL RESULTS Low-cycle Fatigue Lives Relationships between total strain range ∆εt and cycles to failure Nf are shown in Fig. 2 for a comparison with standard specimen. These show the almost straight line in log-log plots and have same slope within the limits of this experiment, although there is a little scatter in fatigue lives at every type of specimen among the materials 11FY and 12FY. It can also be seen from this figure that the reinforcement fiber ends specimen has a shorter fatigue lives than those of standard specimen. It is fundamentally resulted from the difference in fatigue crack initiation and propagation behavior. Reinforcement fiber ends specimen has a shorter fatigue crack initiation lives as compared with standard specimen. And Type-I has a shorter fatigue lives than Type-II. It is concluded here that the reinforcement fiber ends near the surface is the most critical for the low cycle fatigue lives.
RkJQdWJsaXNoZXIy MjM0NDE=