TABLE 1 COMPARISON OF STRESSES BEFORE AND AFTER REPAIR Strain gauge S1 S2 S3 S4 S5 S6 Max. stress without stiffeners (MPa) Measured Not measured Not measured (crack) 50-100 30 50 150 FEM 100 360 110 60 50-60 300 Max. stress with stiffeners (MPa) Measured 100 120 20 30 70 50-70 FEM 100 180 15-20 60 60-80 100 CONCLUSION The paper illustrates the danger of inappropriate design in the case of variable loads. Sharp transition from vertical to horizontal plates at crane leg caused the initiation and growth of fatigue cracks that brought into danger the whole construction. By replacing the plates that contained cracks and applying the stiffeners at the places of cracks initiation, the sources of fatigue damages are removed and the maximum stresses at redesigned construction are lowered to approximately one half of previous values. Having in mind important role of the own weight of construction and inertial forces, the application of electrical devices connected to all actuators was suggested. The purpose of these devices is to turn on the actuators gradually, without jerks, what will generally minimize the influence of inertial forces. Later examinations of the crane construction approved the success of this repair – two years after repair no new cracks were detected. REFERENCES 1. Domazet, Z., Lozina, Z., Pirsic, T., Misina, N., Djukic, P. (1999). FESB Report No. 01/99
RkJQdWJsaXNoZXIy MjM0NDE=