Figure 1. A Schematic of the Modified Mixed-Mode Bend Test Apparatus. RESULTS AND DISCUSSION Static Results Two series of 5 tests were performed on 919HF/HTA to obtain values for the materials tensile and compressive strengths. The results are shown in Table 1. It can be seen that there is relatively little scatter in the results. The standard deviation of the mean tensile strength is 0.04 and of the compressive 0.03, which are approximately 5% of the mean value in both cases. The compressive strength is approximately 20% weaker than the tensile strength but that is to be expected. TABLE 1. STATIC TEST RESULTS FOR 919HF/HTA Test Tensile Failure Stress (GPa) Compressive Failure Stress (GPa) 1 0.760 0.545 2 0.762 0.608 3 0.710 0.592 4 0.750 0.620 5 0.679 0.587 Average (mean) 0.732 0.590 Standard Deviation (%mean) 5.46 5.08 Fatigue Results Tensile fatigue tests A series of tests were carried out at 90% and 80% of the laminates mean tensile strength and all were taken to failure. The fatigue lives for each test are given in Table 2. The scatter in the results of 90% is significant; the standard deviation of the mean is 2682, which is 68% of the mean. It is not unusual to find this amount of scatter in fatigue results at higher stress levels due to the two elements which contribute to the scatter, i.e. the tensile scatter and the fatigue scatter. The scatter in the results at 80% is significantly lower than that for the tests conducted with a peak stress at 90%. The standard deviation is 31,472, which is 44% of the mean life. This reduction in the fatigue scatter agrees with the hypothesis of Barnard et al.(3) that as the peak stress is reduced the amount of static scatter as a proportion of the applied stress decreases and therefore scatter in the fatigue results will also decrease.
RkJQdWJsaXNoZXIy MjM0NDE=