ICF10B

During indentation experiments into Cu thin films with a W superlayer it was found that the crack arrest marks form and correspond exactly to the blister size [13, 14]. Marks are formed of carbon, and outline the crack tip, representing its geometry [13, 14]. CRACK ARREST (FIDUCIAL) MARKS Crack arrest marks were found after the blister removal with an adhesive tape. Scanning electron microscopy showed circles that correspond to the original blister diameter, and those were denoted as crack arrest fiducial marks [13, 14]. Atomic force microscopy was performed to measure the feature geometry, giving a width over 1 µm, and a height ranging from 5 to 15 nm. Contact and deflection AFM images of the partially removed blister showing the fiducial crack arrest marks are presented in Figure 1. It was originally believed that the crack arrest mark is formed by crushed W and/or SiO2 debris during the indentation [13]. More likely, however, radial cracking allowed laboratory air with moisture, hydrocarbons and surface debris to be sucked into the blister [14]. The exact source of contamination would be identified later, but whatever the source is, relatively mobile moisture, hydrocarbons and small debris particles were sucked into the crack tip leaving the fiducial mark detected in Figure 1. Blister Fiducial Mark W SiO2 Figure 1. AFM height and deflection images of partially removed blister, showing fiducial mark underneath.