ICF1001038OR 20μm Fig.11. SEM fractograph of the annular plate. Fig.12. Relation between dimple area fraction and fracture strain. CONCLUSION In this study, the fracture behavior of a corroded annular plate was clarified for the reliability assessment of damaged structure. The main conclusions are as follows. As a result of bend tests, well developed extensive cracking was noted in the high deflection region correlated with varying degree of corrosion damage. From successive observation of crack growth behavior on the corroded surface, it was clearly demonstrated that the multiple cracks, initiated around pits, grew rapidly into large cracks not only by crack growth by itself but also by coalescence with other neighboring cracks under the influence of plastic constraint. Then, it should be emphasized that the development of serious cracking through the coalescence of multiple cracks was considered to be a characteristic event of the corroded component, and was envisaged to occur under a multi-axial stress state depending upon the degree of corrosion damage. REFERENCES [1]. R. E. Peterson(1953), “Stress concentration design factors”, John Wiley & Sons, 136. [2]. R. E. Peterson(1953), “Stress concentration design factors”, John Wiley & Sons, 35.