from the incorporation of MK. The results also show small increases due to increased curing time. Tables 2 and 3 give the results of the CCEL and CCAL fracture tests respectively for 28 and 91 days of curing . FRACTURE TOUGHNESS AND FRACTURE ENERGY It has been reported [9] that the fracture toughness Kc, obtained from the stress intensity factor [7] and the load at failure, did not show significant variation with notch size. This behaviour although not always born out in fracture tests, is in agreement with the notion that Kc is a material property, which should be independent of specimen geometry and notch size. The results presented in this paper were obtained from testing specimens containing symmetrical notches 30 mm deep. It is easily seen (Tables 2 and 3) that Kc increases with increasing MK content for both CCEL and CCAL specimens. This increase is similar to that observed for the compressive strength and is attributed to the pozzolanic activity derived from the MK and the calcium hydroxide liberated during the hydration of the cement and the MK filler effects. The resulting concrete is more densified with the interfacial zones being smaller in thickness thus resulting in more composite action between the paste and the aggregates. The increase in Kc for the specimens tested at 91 days are significantly smaller than those obtained at 28 days. This is not surprising as the pozzolanic activity in concrete due to MK is at its peak at 7-14 days [10]. TABLE 2 FRACTURE RESULTS FROM CCEL SPECIMENS MK (%) Kc (MN/m3/2) Gc N/m Ef N/m Tf 28 day tests 0 5 10 15 0.60 0.78 0.87 0.99 9.87 15.8 19.1 23.5 19.2 24.8 28.8 35.0 1.95 1.57 1.51 1.49 91 day tests 0 5 10 15 0.94 0.97 1.07 1.10 23.6 24.4 28.2 29.0 23.0 25.8 30.8 33.8 0.98 1.06 1.09 1.16 The reported values for Gc were determined using Eqn. 1 with µ=2. Similar variations in Gc to those of Kc occur with increasing MK content. The fracture energy Ef was evaluated from the area under the load-displacement curves recorded during the tests. The values for Ef obtained from the CCAL specimens are considerably higher than those recorded from the CCEL specimens. This is attributed to the fact that CCAL specimens are much more rigid than CCEL specimens, which was evidenced by the greater load sustainability before failure in the case of CCAL testing. It has been reported [9,11] that both Gc and Ef converge to the same value as the notch size increases. For short cracks, however, Ef is generally greater than Gc. The differences in the values of the fracture energy determined by Gc and Ef are attributed to the assumption of a planar fracture surface in the determination of Ef. In practice the fracture surface is tortuous and can be several times greater than that assumed [12,13].
RkJQdWJsaXNoZXIy MjM0NDE=