ICF10B

and the orientation of the martensite plates; however, it is still possible that the plates nucleate fracture and this is a topic of future research. Figure 3 shows high resolution images from the [148] crystals, comparing the cleavage markings for samples aged (a) 1.5 hr @ 723 K versus (b) 1.5 hr @ 823 K. The orientations of the markings are the same for samples aged under the two different conditions (they are mirror (a) (b) Figure 3: SEM image of cleavage patterns on the fracture surfaces of the [148] crystal aged (a) aged 1.5 hr @ 723 K or (b) 1.5 hr @ 823 K. images of each other due to the opposite choice of fracture sample halves). However, the cleavage markings in Figure 3b are wavy, and have considerable surface roughness compared to the distinct markings in Figures 3a. In general, a rougher appearance to the fracture surface implies an increased amount of local plastic flow during fracture. In other words, even though the crystallographic aspects of the cleavage fracture are still evident in the samples with the larger Ti3Ni4 precipitates, the cleavage occurs with more local distortion than in samples with relatively smaller Ti3Ni4 precipitates. We assert that the increased distortion during cleavage in the samples with the larger precipitates is caused by the local composition changes during the aging process. As Ti3Ni4 precipitates coarsen, the local Ni concentration is decreased since the precipitates are Ni rich compared to the matrix. The observations in Figure 3 clearly imply that supersaturated Ni-rich NiTi is inherently more brittle than equiatomic NiTi. Figure 4 lends further support to the above hypothesis on the different fracture mechanisms in the NiTi alloys given the two different aging treatments. The image in Figure 4a was taken in a region of the sample where the Ti3Ni4 precipitates are much larger than the average size for the 1.5 hr @ 723 K treatment. Conversely, the visible precipitates in the image in Figure 4b are more typical of the precipitates found in the samples aged 1.5 hr @ 823 K. In the NiTi aged 1.5 hr @ 723 K the cleavage path generally cuts straight through the regions with the large precipitates, leaving negligible voids surrounding them. However, in the alloy aged 1.5 hr @ 823 K the cleavage path is hardly recognizable, except for faint lines, and significant dimples surround the larger precipitates. We note that precipitates much smaller than the ones visible in the holes in figure 4a may exist in the surrounding material. The local deformation characteristics near these smaller precipitates (50100 nm), coupled with the high Ni concentration of the surrounding matrix, are responsible for the cleavage fracture in Figure 4a versus the ductile fracture in Figure 4b. Such observations are

RkJQdWJsaXNoZXIy MjM0NDE=